(1) The licensee must perform the routine RF environmental evaluation prescribed by Sec. 1.1307 (b) of this chapter, if the power of the licensee's station exceeds the limits given in the following table:
| |
Wavelength Band |
Evaluation Required if Power* (watts) Exceeds |
| MF |
160 meters |
500 |
| HF |
80 meters |
500 |
|
75 meters |
500 |
| |
40 meters |
500 |
| |
30 meters |
425 |
| |
20 meters |
225 |
| |
17 meters |
125 |
| |
15 meters |
100 |
| |
12 meters |
75 |
| |
10 meters |
50 |
| VHF |
All bands |
50 |
| UHF |
70 cm |
70 |
| |
33 cm |
150 |
| |
23 cm |
200 |
| |
13 cm |
250 |
| SHF |
All bands |
250 |
| EHF |
All bands |
250 |
|
Repeater
stations
|
All bands |
•non-building mounted antennas: height above ground level to lowest point of antenna < 10 m and power > 500 W ERP
•building mounted antennas: power > 500 W ERP
|
|
* Power = PEP input to antenna except, for repeater stations only, power exclusion is based on ERP (effective radiated power).
|
(2) If the routine environmental evaluation indicates that the RF electromagnetic fields could exceed the limits contained in § 1.1310 of this chapter in accessible areas, the licensee must take action to prevent human exposure to such RF electromagnetic fields. Further information on evaluating compliance with these limits can be found in the FCC's OET
Bulletin Number 65, "Evaluating Compliance with FCC-Specified Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields."
[54 FR 25857, June 20, 1989, as amended at 55 FR 20398, May 16, 1990; 61 FR 41019, Aug. 7, 1996; 62 FR 47963, Sept. 12, 1997; 62 FR 49557, Sept. 22, 1997; 62 FR 61448, Nov. 18, 1997]